Conference Agenda
Overview and details of the sessions of this conference. Please select a date or location to show only sessions at that day or location. Please select a single session for detailed view (with abstracts and downloads if available).
|
Session Overview |
| Date: Tuesday, 10/June/2025 | |||
| 7:00am - 8:00am |
Breakfast Location: Osprey, Caracara, Sandpiper & Seagull |
||
| 7:00am - 5:00pm |
Registration Location: Board Room |
||
| 8:00am - 9:00am |
Is Renewable Energy Running Out of Wind? Location: Egret & Heron & Pelican Chair: Kevin Alewine, Shermco Industries, United States of America |
||
| 9:00am - 10:00am |
Rotating Machines Location: Egret Chair: Dr. Aleksandr Khazanov, National Electric Coil, United States of America Inverter voltage endurance testing of twisted pairs according IEC 60851 with a self-developed, adjustable generator 1: University of Applied Sciene Hannover, Germany; 2: Axalta Coating Systems, Germany 9:30am - 10:00am On-line Partial Discharge Diagnosis on Stator Winding Insulation: Impacts of Voltage Distortion and Winding Temperature Central Research Institute of Electric Power Industry, Japan |
Testing, Diagnostics, and Condition Assessment Location: Heron Chair: James Steele, Southwire, LLC, United States of America Creepage Discharge Characteristics of Solid Liquid Interface in Subsea Cable Connectors 1: The University of Manchester, UK; 2: Siemens Energy Limited, Ulverston, UK 9:30am - 10:00am Partial Discharge Measurement Experiences on Field Maintenance and in Workshop Fault Investigations of Power Transformers and Shunt Reactors - Case Studies Turkish Electricity Transmission Corporation - TEİAŞ, Turkiye |
Outdoor Insulation Location: Pelican Chair: Valeria Blaze, Manitoba Hydro, Canada Assessing Induced Voltage Risks on Pipeline Insulation Due to Electrical Disturbances Magna IV Engineering, Canada |
| 10:00am - 10:30am |
Coffee Break Location: Spoonbill & Ibis |
||
| 10:30am - 12:00pm |
Rotating Machines Location: Egret Chair: Joseph Williams, Electrolock Inc., United States of America A Novel Approach to Roebel Bar Stator Winding Repair in a Large Hydro Pump Generator Hydroelectric Design Center, US Army Corps of Engineers 11:00am - 11:30am Investigation of failure mechanisms of stator winding and stator core. Protocol for repair and acceptance testing of stator winding and stator core. Asset management strategy for stator assembly for machines above 100MVA. 1: Voith; 2: Rio Tinto 11:30am - 12:00pm Stator Core End Region Heating in Large Generators: A Case Study National Electric Coil, United States of America |
Testing, Diagnostics, and Condition Assessment Location: Heron Chair: Valeria Blaze, Manitoba Hydro, Canada Polarity of Measured PD Impulses - How Useful is it ? 1: OMICRON Canada; 2: OMICRON Austria 11:00am - 11:30am Detection of Partial Discharges Occurring in Oil-Filled Cable Joints Arranged in a Mock-up Tunnel Using a Radio Interferometer System 1: Tokushima University, Japan; 2: TEPCO Power Grid, Inc., Japan 11:30am - 12:00pm Automatic Insulation Diagnosis Using the Characteristics of Electromagnetic Waves due to Partial Discharges Occurring in Propulsion Coils Tokushima University, Japan |
Power, Distribution and Instruments Transformers Location: Pelican Chair: Dr. Diego Robalino, MEGGER Group, United States of America Improvement of Karl Fischer Moisture Measurements During Accelerated Aging Testing of Transformer Insulating Systems Weidmann Electrical Technology Inc., United States of America 11:00am - 11:30am Investigating the Effects of Moisture Distribution on the Electric Field and Leakage Current of Power Transformer Bushings 1: THWS, Germany; 2: Department of Electrical Engineering, Babol Noshirvani University of Technology, Iran; 3: University of Tehran, College of Engineering School of Electrical and Computer Engineering, Iran |
| 12:00pm - 1:30pm |
Lunch |
||
| 1:30pm - 3:00pm |
Rotating Machines Location: Egret Chair: Paul Gaberson, IEEE, United States of America Influence of Applied Waveforms and Pressure on Partial Discharge Characteristics in a Converter-Fed Motor Winding Model for Electric Propulsion Aircraft 1: The University of Tokyo; 2: Japan Aerospace Exploration Agency 2:00pm - 2:30pm Investigation of Optimal Electrical Insulation Systems of Stator Windings for Inverter-Fed Motors 1: TMEIC Corporation, Japan; 2: Mitsubishi Electric Corporation; 3: Kyushu Institute of Technology 2:30pm - 3:00pm PDIV Prediction and Tests on the Insulation for Aerospace Electro-Hydrostatic Actuator (EHA)Motors 1: AVIC Xi'an Flight Automatic Control Research Institute; 2: Sichuan University |
Testing, Diagnostics, and Condition Assessment Location: Heron Chair: Prof. Davide Fabiani, University of Bologna, Italy Study on Dielectric Frequency Response Analysis of Transformer Insulation Megger 2:00pm - 2:30pm A Comprehensive Approach to DGA: Advancing Transformer Diagnostics in the Era of Modern Power Systems Consulting Marius Grisaru, Israel 2:30pm - 3:00pm Modeling Dielectric Breakdown of Voids in Ground-Wall Insulation Systems: Initial Studies 1: Aaron Mosier Consulting; 2: EMC, Electric & Motor Contracting, Co.; 3: Frosty's Zap Lab, LLC |
Cables, Accessories, and Power Electronics Location: Pelican Chair: Mark Fenger, Kinectrics Inc., Canada Effect of transverse compression on the dielectric breakdown of power cable with ethylene propylene rubber (EPR) insulation Oak Ridge National Laboratory, United States of America 2:00pm - 2:30pm Life Cycle Analysis Considerations for a Resilient Energy Grid Southwire, LLC, United States of America 2:30pm - 3:00pm Degradation Characteristics of Insulation Discharge at the Interface of Moisture-Affected Cable Accessories Sichuan University: Chengdu, Sichuan, CN |
| 3:00pm - 3:30pm |
Coffee Break Location: Spoonbill & Ibis |
||
| 3:30pm - 4:30pm |
Rotating Machines Location: Egret Chair: Shannon Sitler, GE Vernova, United States of America Forming Slot Liner Insulation Materials into Electrical Machines: Manufacturing Considerations and Effects on Performance 1: Warwick Manufacturing Group, University of Warwick; 2: Safran Electrical and Power UK 4:00pm - 4:30pm Overshoot and Duty Cycle Effects of Wide-Bandgap Drives on Hairpin Winding in EVs University of Waterloo, Canada |
Green Energy Location: Heron Chair: Mark Fenger, Kinectrics Inc., Canada Charge Transport in Composite Natural Ester Fluid Ahmadu Bello University, Zaria 4:00pm - 4:30pm Evaluation of Wind Turbine Electrical and Mechanical Defects Due to Nacelle Circulating Currents MotorDoc LLC, United States of America |
|
| 3:30pm - 5:30pm |
Testing, Diagnostics, and Condition Assessment Location: Ibis Chair: Samuel W. Glass, Pacific Northwest National Laboratory, United States of America Thermal fault diagnostics for different transformer insulation systems VEGOOR, Brazil 4:00pm - 4:30pm Evaluating Turn Insulation Degradation Using Sweep Frequency Response Analysis 1: École de Technologie Supérieure; 2: Institut de Recherche d'Hydro-Québec, Canada; 3: Hydro-Québec 4:30pm - 5:00pm Analysis techniques for pulse sequences in medium and high voltage DC and battery energy storage systems. O&M Korea, Korea, Republic of (South Korea) 5:00pm - 5:30pm Analysis of Insulation Electrical Stress in Electric Vehicle Drive Motors under Repetitive Square Wave Voltage Conditions 1: State Key Laboratory of Engine and Powertrain System, Weichai Power Co. Ltd, Weifang Shandong, China; 2: SICHUAN UNIVERSITY, People's Republic of China |
||
| 7:00pm - 7:30pm |
Open Bar Location: Pre-Function Gallery |
||
| 7:30pm - 10:00pm |
Banquet Location: Ibis & Egret & Heron |
||
