Session | |||||||||||||
RF13: Rapid Fire Poster Presentations - Topic Lung & Materials/Testing
| |||||||||||||
Presentations | |||||||||||||
3:30pm - 3:35pm
INFLUENCE OF LENGTH OF SIDE HOLE PORTION AND INTERVAL OF SIDE HOLES IN DRAINAGE CANNULAE FOR V-V ECMO: EFFECT ON RECIRCULATION RATE AND BLOOD OXYGENATION Teikyo Heisei University, Japan
3:35pm - 3:40pm
Assessing realism of extracorporeal membrane oxygenator simulators – Development and application of an objective fidelity classification framework 1Engineering Organ Support Technologies group, University of Twente, The Netherlands; 2Dept. of cardio-thoracic surgery, Thorax Centrum Twente, Medisch Spectrum Twente, The Netherlands
3:40pm - 3:45pm
Effect of cannula tip positions in pulmonary arterial cannulation on blood flow and gas exchange using computational fluid dynamics analysis 1Institute for Bioengineering (IfB), Faculty for Medical Engineering and Techno-Mathematics, FH Aachen University of Applied Sciences, Jülich, Germany; 2Department of Orthopedics, Trauma and Reconstructive Surgery, RWTH Aachen University, Aachen, Germany; 3Department of Thoracic Surgery, RWTH Aachen University, Aachen, Germany
3:45pm - 3:50pm
Development of aggressive treatment to administer drugs directly into the trachea of patients on ECMO Asahikawa Medical University, Japan
3:50pm - 3:55pm
DESIGN AND IN VITRO TESTING OF A VALVELESS UNDULATING DISPLACEMENT PUMP FOR EXTRACORPORAL MEMBRANE OXYGENATION 1Deutsches Herzzentrum der Charité, Institute of Computer-assisted Cardiovascular Medicine, Biofluid Mechanics Laboratory, Augustenburger Platz 1, 13353, Berlin, Germany;; 2Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany
3:55pm - 4:00pm
IS THIS THE SUMMIT OF EXTRACORPOREAL GAS EXCHANGE PERFORMANCE? 1ECC Lab, Institute of Physiology, Medical Faculty, RWTH Aachen University, Germany; 2Department of Thoracic Surgery, Medical Faculty, RWTH Aachen University, Germany
4:00pm - 4:05pm
A bioreactor to investigate the mechanical influence on cell mineralization in lattice bone implants 1Medical University of Vienna, Vienna, Austria; 2Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria; 3Austrian Cluster for Tissue Regeneration, Vienna, Austria
4:05pm - 4:10pm
GHOST CELLS AS A TWO-PHASE BLOOD ANALOG FLUID — VISUALIZATION OF MECHANICAL HEMOLYSIS Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Forckenbeckstr. 55, Aachen, 52074, Germany
4:10pm - 4:15pm
ANATOMY AND PHYSIOLOGY BASED MOCK LOOP FOR CARDIAC IMPLANT DEVELOPMENT 1Deutsches Herzzentrum der Charité, Institute of Computer-assisted Cardiovascular Medicine, Biofluid Mechanics Laboratory, Augustenburger Platz 1, 13353 Berlin, Germany; 2Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt Universität zu Berlin, Charitéplatz 1, 10117 Berlin, Germany
4:15pm - 4:20pm
THE ROLE OF NANOMATERIALS IN THE FABRICATION OF MEDICAL DEVICES ISS, Italy
4:20pm - 4:25pm
Wireless-controlled bidirectional pumping system for artificial organs with hydraulic actuation The BioRobotics Institute, Scuola Superiore Sant’Anna, Pontedera (Pisa), Italy
4:25pm - 4:30pm
NUMERICAL ASSESSMENT OF THE EFFICIENCY OF A NEW MINIMALLY INVASIVE PROBE FOR THE ISOLATION OF CIRCULATING TUMOR CELLS 1Deutsches Herzzentrum der Charité, Institute of Computer-assisted Cardiovascular Medicine, Biofluid Mechanics Laboratory, ,Augustenburger Platz 1, Berlin 13353, Germany; 2Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Institute of Computer-assisted Cardiovascular Medicine, Charitéplatz 1, 10117 Berlin, Germany; 3Invicol GmbH, Köpenicker Straße 325, Berlin 12555, Germany
4:30pm - 4:35pm
Baroreflex control implementation and performance evaluation of a cardiovascular hybrid mock circulation loop Politecnico di Milano, Italy
|