CIGRE 2025 International Symposium
Palais des Congrès de Montréal, Québec, Canada
From September 29 to October 2, 2025
Conference Agenda
Overview and details of the sessions of this conference. Please select a date or location to show only sessions at that day or location. Please select a single session for detailed view (with abstracts and downloads if available).
|
Session Overview | |
Location: Room 520C |
Date: Monday, 29/Sept/2025 | |
2:00pm - 4:00pm |
A1-1: Partial discharge, AI and ML applications Location: Room 520C Pulse Shape Analysis and Advanced Techniques for Partial Discharge Measurement in Rotating Machines CEPEL, Brazil 2:15pm - 2:30pm Locate Hydrogenerator Stator Failure by Partial Discharge Monitoring, Dielectric Test and Corona Inspection Eletrobras Eletronorte, Brazil 2:30pm - 2:45pm Evaluation of the high-frequency electrical behavior of stator windings of 18 kV by measuring partial discharges and complement analysis using the EMTP/ATP Cepel, Brazil 2:45pm - 3:00pm Evaluation of the Discharges Criticality in the Stator Winding End Corona Protection Region 1: Eletrobras Eletronorte, Brazil; 2: Trassínio Consultoria Ltda, Brazil 3:00pm - 3:15pm Machine Learning Techniques for Identifying Partial Discharge Sources from Phase-Resolved Partial Discharge Patterns Hydro-Quebec, Canada 3:15pm - 3:30pm Applicability of AI Tools to Analyze Phase-Resolved Partial Discharge from Motor and Generator Stator Windings 1: Stone Dielectrics, Canada; 2: Iris Power L.P., Canada 3:30pm - 3:45pm AI-Driven Fault Detection in Hydroelectric Generators: Integrating Variational Autoencoders with Stray Flux Analysis 1: Ecole de technologie supérieure, Canada; 2: Hydro Québec Research Institute (IREQ) 3:45pm - 4:00pm Software Design of Turbine Generator Shaft Earthing-Brush Fault Types Diagnosis System Based on Deep Learning 1: Eskom RT&D, South Africa; 2: Eskom NTCSA, South Africa |
4:30pm - 6:00pm |
A1-2: Partial discharge, AI and ML applications Location: Room 520C Overview of the Advanced Diagnosis of Generators (DIAAA) Platform for Digital Twin Application Hydro-Québec, Institut de Recherche, Canada 4:45pm - 5:00pm Graph neural network auto encoder and deep modular learning for prognostics and health management of hydrogenerators Hydro-Québec, Canada 5:00pm - 5:15pm Understanding and Extending Hydro-Generator Capability Through Thermal Diagnostics and Probabilistic Modelling 1: Hydro-Québec, Canada; 2: École de Technologie Supérieure, Canada 5:15pm - 5:30pm Advanced health monitoring of hydrogenerators using VAE including KAN for fault detection and diagnosis using stator vibration signals 1: Ecole de Technologie Supérieure, Canada; 2: Hydro-Québec Research Center, Canada 5:30pm - 5:45pm Grid Resilience and Renewable Integration: India's Transition to a Sustainable Power System NHPC Limited, India 5:45pm - 6:00pm Requirements for Power System Stabilizer Tuning 1: Universidad Pontificia Comillas, Spain; 2: Cresym; 3: RTE France |
Date: Tuesday, 30/Sept/2025 | |
1:30pm - 3:30pm |
A1-3: Condition monitoring & assessment Location: Room 520C Development of a Diagnostic Strategy for Large Hydrogenerator Rotors Hydro-Quebec, Canada 1:45pm - 2:00pm Advancing Reliability: Case Studies on Offline Diagnostic Testing for High-Voltage Turbo Generators Kinectrics, Canada 2:00pm - 2:15pm Diagnostic Methods Of Synchronous Machines With Salient Poles Using Airgap Flux, Pole Leading Edge Induction Voltage, Stray Flux Measurement And Ampere-Turns measurements 1: Institut de recherche d’Hydro-Québec(IREQ), Varennes, Canada; 2: École de technologie Supérieure, Montréal, Canada 2:15pm - 2:30pm Hydro-generator condition-based monitoring system modernization for maintenance optimization 1: Qualitrol - Iris Power, Canada; 2: Veski 2:30pm - 2:45pm Importance of Polarity test of stator winding as pre-commissioning test for Hydro Generators NHPC Limited, India 2:45pm - 3:00pm Hydro-unit increased vibration case study 1: Veski, Croatia; 2: Qualitrol - IRIS Power, Canada 3:00pm - 3:15pm Overview of Localized Partial Discharge Activity Analysis with Results from Dissection of Individual Stator Bars and Coil 1: École de Technologie Supérieure, Canada; 2: Hydro-Québec, Canada 3:15pm - 3:30pm Evaluation of Turbo Generator Stator Bushing Condition Monitoring 1: Eskom RT&D, South Africa; 2: Eskom RT&D, South Africa; 3: Eskom RT&D, South Africa; 4: Eskom Generation, South Africa |
4:00pm - 6:00pm |
A1-4: Condition monitoring & assessment Location: Room 520C Rotor Temperature Continuous Monitoring using Fiber Bragg Gratings 1: Institut de recherche d'Hydro-Québec; 2: Hydro-Québec, Canada; 3: RPR Hydro 4:15pm - 4:30pm Environmental Impacts of Manufacturing and Renovation of High Voltage Rotating Machines and Power Plants National Electric Coil, United States of America 4:30pm - 4:45pm Proposal for Methodological Note of Life Cycle Assessment: Eco-design of Turbogenerator EDF, France 4:45pm - 5:00pm Optimization process applied to Synchronous Generator designs to improve machine key parameters to suit Synchronous Condenser applications Baker Hughes - Brush Power Generation 5:00pm - 5:15pm The Lack of Air-gap Orthogonality and Parallelism Impact Upon the Unbalanced Magnetic Pull 1: Trassínio Consultoria Ltda, Brazil; 2: Trassínio Consultoria Ltda, Brazil; 3: UNIFEI - Universidade Federal de Itajubá 5:15pm - 5:30pm Research on Stagnation Zone Based on RTD Method and Improvement of Coupled Fluid-solid Heat Transfer Considering Mesh Morphing 1: wuhan university, China; 2: Harbin Electric Machinery Company Limited , China 5:30pm - 5:45pm Development of the new Type of Carbon Brush for Adjustable Speed Generator-Motor Toshiba Energy Systems & Solutions Corporation, Japan 5:45pm - 6:00pm Endurance tests of power electrical connections in bolted assembly EDF, France |
Date: Wednesday, 01/Oct/2025 | |
10:30am - 12:15pm |
A1-5: Asset management Location: Room 520C REPLACING DIAMOND COIL STATOR WINDINGS WITH ROEBEL HALF-BAR TYPE ARMATURE WINDINGS TO MITIGATE THE FREQUENT STATOR FAILURES CAUSED BY INTER-TURN FAULTS : NHPC EXPERIENCE NHPC LIMITED, India 10:45am - 11:00am Stator Windings Neutral Inversion Case Study DMI Energy, Canada 11:00am - 11:15am The Need for a Classification of Different Kinds of Partial Discharges to Provide Effective Reinvigoration of the Corona Effect Preventive System in Stator Winding Maintenance Process Trassínio Consultoria Ltda, Brazil 11:15am - 11:30am Assessment of the Stator Insulation System of Synchronous Compensators to Determine the Need for Modernization Eletrobras-Eletronorte, Brazil 11:30am - 11:45am Insulation Systems for Motors, Generators and Synchronous Condensers – Contributions to writing Specifications for Services and new Windings. WEG, Brazil 11:45am - 12:00pm Enhancing combined cycle power plant Efficiency Through Advanced Fogging Techniques: GE 13E2 gas turbine no.5 in Samra/Jordan as a case study. 1: Samra Electrical Power Company SEPCo., Jordan, Hashemite Kingdom of; 2: Hussien technical university / Jordan 12:00pm - 12:15pm Méthode d’atténuation des dangers liés aux éclats d’arc de grande énergie Hydro Quebec, Canada |
1:30pm - 3:30pm |
A1-6: Asset management Location: Room 520C STRATEGIC PLANNING & CHALLENGES FOR INSTALLATION OF GENERATOR CIRCUIT BREAKERS (GCBs) TO IMPROVE PROTECTION OF THE GENERATING UNIT, BY CLEARING POTENTIAL HARMFUL SHORT-CIRCUIT FAULTS IN THE HYDRO POWER STATIONS NHPC LIMITED, India 1:45pm - 2:00pm Design And Analysis of New Bladeless Vortex Wind Turbine Hatch, Canada 2:00pm - 2:15pm Dynamic State Estimation of Doubly Fed Induction Generator based on Robust Particle Filtering 1: Power System Consultant (PSC), Canada; 2: FortisAlberta Inc., Canada 2:15pm - 2:30pm CMS support in preventive maintenance actions to extend the useful life of direct drive turbine main bearings 1: AQTech Power Prognostics, Brazil; 2: CEMIG 2:30pm - 2:45pm Case study: supporting the maintenance management of wind turbine fleets with gearbox defect patterns using condition monitoring systems 1: AQTech Power Prognostics, Brazil; 2: CGN Brazil Energy, Brazil 2:45pm - 3:00pm Practical Applications of Electrical and Current Signature Analysis in DFIG Wind Generator and Powertrain Reliability Evaluation MotorDoc LLC, United States of America 3:00pm - 3:15pm Digital twin model for predicting the energy generation from the wind turbine Monenco Iran, Iran, Islamic Republic of |